DM7000 Defibrillator
Home » Products » Surgery & ICU Equipment » Defibrillator » DM7000 Defibrillator

loading

Share to:
sharethis sharing button

DM7000 Defibrillator

Availability:
Quantity:
  • DM7000

Specifications:

Defibrillator

Energy Select:

External: 2, 5, 7, 10, 20, 30, 50,70, 100, 150, 200, 300, 360 J.

Charge Time:

< 7 seconds @ 360 J (with a Smart Pak Plus battery after 15discharges).

< 9 seconds @ 360 J (with a Super Pac battery after 15 discharges).

< 15 seconds @ 360 J (no battery, 90% AC mains voltage)

Charge Indicator: Audible and graphic.

Output: Adult paddles, pediatric adapter and multipurpose hands-free adapter available.

Synchronizer: Delivers energy within 60 msec.

Disarm: Front panel switch.

 

Monitor/Display

Input: 3-lead, 5-lead, patient cable, paddles, or multi-purpose hands-free adapter.

Size: 6.5 inches (16.5 cm) diagonal, non-fade.

Type: color (TFT)

Display Resolution: 800 x 600 pixels.

Sweep Speed: 12.5mm/s,25mm/s,50mm/s

Lead Selections: Paddles(Pads), I, II, III, AVR, AVL, AVF, V.

Heart Rate Meter: 20 to 300 BPM.

Heart Rate Alarms: User-selectable.

Size: 0.125, 0.25, 0.5, 1, 2, 4 cm/mv and auto-ranging.

Aspect Ratio: 0.5, 0.1, 0.4, 0.8, 1.6, respectively.

ECG Output: 1 V/mV.


Alarms

Heart Rate, BP, SpO2, Resp & Temp Alarm:

Audible: 5 pulse, 800 tone, with a PW of 150 m sec, a PRI of 225m sec, and a repetition interval of 10 seconds. 

Visual: Heart Rate Alarm causes the displayed heart rate to flash at 2 Hz. This display is located at the top of the 

display and is 0.4"high and 0.28 to 0.840" wide depending on number of digits in the heart rate. Color is amber, 

black, white, or whatever the color the display text is.

Lead Fault Alarm:

Audible: 3 pulse, 500 Hz, triplet tone with a PW of 200 m sec, aPRI of 310 msec. When the HR alarm is set or 

the pacer is on, the lead fault one repeats at a repetition interval of 20 seconds.

Visual: Lead Fault condition causes a ”LEAD FAULT” message to be displayed on the trace along with a dashed 

line the width of the trace. The text is 0.18" high and is the color of the display text. The dashed line is 5" long, the 

width of the display. The signal is not modulated.

Physiological Alarms (SpO2):

Audible: See Heart Rate Alarm

Visual: Physiological alarms cause the displayed parameter to flash at 2 Hz. Color is amber, white or the same as 

the display colored text.

Mute Duration: 90 seconds.