XM101C
Product Specification
● Generator output: 5.0 kW
● kV range: 40 kV - 120 kV in 1kv steps
● mA range: 25~100 mA
● Exposure time: 4 films per min, less than 20 ms per film
● X-ray tube: Stationary anode tube with a focal spot of 1.5*1.5 mm
●Collimator: Bright field light beam collimator with 120 W halogen lamp and auto shut-off facility.
●Power requirements: Single phase 220 V +/- 10% Voltage tolerance; 50 Hz power supply
●Mobile stand: Light-weight, low height mobile and easily maneuverable stand.
● The mobile radiographic unit also include a handheld control and a microwave wireless remote control for the 20-meter microwave remote Without the restriction of Barriers and directional, different from the infrared remote control . Grids reduce the fog line filters and raise the degree of scattering contrast.
●The unit is provided with a line (power) cord of acceptable durability, quality, length and is secured with adequate strain reliefs
●The unit include, power plugs that are sufficient for the maximum voltage and current of the unit.
●The maximum distance from the ground: ≥2000mm, and minimum distance from the ground: ≤500mm. Rotating around the horizontal axis 180 °, rotation around the vertical: ± 90 °, the collimator can rotate 180 °, column can rotate ± 90 °.
Product Specification
● Generator output: 5.0 kW
● kV range: 40 kV - 120 kV in 1kv steps
● mA range: 25~100 mA
● Exposure time: 4 films per min, less than 20 ms per film
● X-ray tube: Stationary anode tube with a focal spot of 1.5*1.5 mm
●Collimator: Bright field light beam collimator with 120 W halogen lamp and auto shut-off facility.
●Power requirements: Single phase 220 V +/- 10% Voltage tolerance; 50 Hz power supply
●Mobile stand: Light-weight, low height mobile and easily maneuverable stand.
● The mobile radiographic unit also include a handheld control and a microwave wireless remote control for the 20-meter microwave remote Without the restriction of Barriers and directional, different from the infrared remote control . Grids reduce the fog line filters and raise the degree of scattering contrast.
●The unit is provided with a line (power) cord of acceptable durability, quality, length and is secured with adequate strain reliefs
●The unit include, power plugs that are sufficient for the maximum voltage and current of the unit.
●The maximum distance from the ground: ≥2000mm, and minimum distance from the ground: ≤500mm. Rotating around the horizontal axis 180 °, rotation around the vertical: ± 90 °, the collimator can rotate 180 °, column can rotate ± 90 °.