Hydrogen Peroxide Low Temperature Plasma Sterilizer (Cassette Type)

Availability:
Quantity:

Description

● Low temperature  sterilization  process at < 55 C (131° F)

● Uses vaporized hydrogen peroxide for the terminal sterilization of packaged, resuseable medical devices

● No secondary means of reducing hydrogen peroxide residual.

● Returns to atmospheric pressure by use of HEPA filtered room air.

● Releases only water vapor and oxygen (no drain required). No toxic residues.

● Siemens PLC control with 7” display of cycle phases and parameters.

● Integrated thermal printer

● USB port for processing data download .

● Easy to install without civil / plumbing work.

Specification

● Power supply :AC 220V 50 Hz or AC 110V 60 Hz , Standard plug . without the need of extra civil work

● Automatic lifting door with movable casters

● Sterilization room material : 5052 Aluminum alloy

● Uses 60% H2O2 solution as the sterilization agent

● Rapid Mode & Strengthen Mode; short cycle 35 minutes , long cyle 55 minutes; A cycle for all device

● Working temperature during 45–55°C

● Have memory storage for at least 500 sterilization cycles

● Suitable for sterilization of metal & non-metal medical devices like rigid endoscopes, metal &plastic lumen items , heat & moisture sensitive instruments etc

● Siemens PLC ,touch screen control The process is fully automatic;

● Built-in thermal printer , real-time print out sterilization status . USB port available for historical data download .

● Displays for chamber pressure and temperature ,processing phases and alarm errors .

● Vacuum pump to remove air and moisture from the chamber , RF generator produce plasma in 50Pa vacuum condition .

● Audible and visual alarm for : Temperature , Pressure,Vacuum condition ,self-diagnostic capability for troubleshooting.

● The sterilizer door cannot be opened if either electrical power or air pressure is lost during sterilizer operation.

Capacity list

Model

Capacity

Chamber   Size

(cm)

Available

Power

(KW)

H2O2

Consumption

D100

100   liter

70*43*36

80L

3.8

5.0ml/pc

D130

130   liter

75*45*40

117L

4.2

5.5ml/pc

D220

190   liter

82*51*46

150L

5.0

8.0ml/pc

Power   supply: AC 220V 50Hz or AC 110V 60Hz