DM7000
Specifications:
Defibrillator
Energy Select:
External: 2, 5, 7, 10, 20, 30, 50,70, 100, 150, 200, 300, 360 J.
Charge Time:
< 7 seconds @ 360 J (with a Smart Pak Plus battery after 15discharges).
< 9 seconds @ 360 J (with a Super Pac battery after 15 discharges).
< 15 seconds @ 360 J (no battery, 90% AC mains voltage)
Charge Indicator: Audible and graphic.
Output: Adult paddles, pediatric adapter and multipurpose hands-free adapter available.
Synchronizer: Delivers energy within 60 msec.
Disarm: Front panel switch.
Monitor/Display
Input: 3-lead, 5-lead, patient cable, paddles, or multi-purpose hands-free adapter.
Size: 6.5 inches (16.5 cm) diagonal, non-fade.
Type: color (TFT)
Display Resolution: 800 x 600 pixels.
Sweep Speed: 12.5mm/s,25mm/s,50mm/s
Lead Selections: Paddles(Pads), I, II, III, AVR, AVL, AVF, V.
Heart Rate Meter: 20 to 300 BPM.
Heart Rate Alarms: User-selectable.
Size: 0.125, 0.25, 0.5, 1, 2, 4 cm/mv and auto-ranging.
Aspect Ratio: 0.5, 0.1, 0.4, 0.8, 1.6, respectively.
ECG Output: 1 V/mV.
Alarms
Heart Rate, BP, SpO2, Resp & Temp Alarm:
Audible: 5 pulse, 800 tone, with a PW of 150 m sec, a PRI of 225m sec, and a repetition interval of 10 seconds.
Visual: Heart Rate Alarm causes the displayed heart rate to flash at 2 Hz. This display is located at the top of the
display and is 0.4"high and 0.28 to 0.840" wide depending on number of digits in the heart rate. Color is amber,
black, white, or whatever the color the display text is.
Lead Fault Alarm:
Audible: 3 pulse, 500 Hz, triplet tone with a PW of 200 m sec, aPRI of 310 msec. When the HR alarm is set or
the pacer is on, the lead fault one repeats at a repetition interval of 20 seconds.
Visual: Lead Fault condition causes a ”LEAD FAULT” message to be displayed on the trace along with a dashed
line the width of the trace. The text is 0.18" high and is the color of the display text. The dashed line is 5" long, the
width of the display. The signal is not modulated.
Physiological Alarms (SpO2):
Audible: See Heart Rate Alarm
Visual: Physiological alarms cause the displayed parameter to flash at 2 Hz. Color is amber, white or the same as
the display colored text.
Mute Duration: 90 seconds.
Specifications:
Defibrillator
Energy Select:
External: 2, 5, 7, 10, 20, 30, 50,70, 100, 150, 200, 300, 360 J.
Charge Time:
< 7 seconds @ 360 J (with a Smart Pak Plus battery after 15discharges).
< 9 seconds @ 360 J (with a Super Pac battery after 15 discharges).
< 15 seconds @ 360 J (no battery, 90% AC mains voltage)
Charge Indicator: Audible and graphic.
Output: Adult paddles, pediatric adapter and multipurpose hands-free adapter available.
Synchronizer: Delivers energy within 60 msec.
Disarm: Front panel switch.
Monitor/Display
Input: 3-lead, 5-lead, patient cable, paddles, or multi-purpose hands-free adapter.
Size: 6.5 inches (16.5 cm) diagonal, non-fade.
Type: color (TFT)
Display Resolution: 800 x 600 pixels.
Sweep Speed: 12.5mm/s,25mm/s,50mm/s
Lead Selections: Paddles(Pads), I, II, III, AVR, AVL, AVF, V.
Heart Rate Meter: 20 to 300 BPM.
Heart Rate Alarms: User-selectable.
Size: 0.125, 0.25, 0.5, 1, 2, 4 cm/mv and auto-ranging.
Aspect Ratio: 0.5, 0.1, 0.4, 0.8, 1.6, respectively.
ECG Output: 1 V/mV.
Alarms
Heart Rate, BP, SpO2, Resp & Temp Alarm:
Audible: 5 pulse, 800 tone, with a PW of 150 m sec, a PRI of 225m sec, and a repetition interval of 10 seconds.
Visual: Heart Rate Alarm causes the displayed heart rate to flash at 2 Hz. This display is located at the top of the
display and is 0.4"high and 0.28 to 0.840" wide depending on number of digits in the heart rate. Color is amber,
black, white, or whatever the color the display text is.
Lead Fault Alarm:
Audible: 3 pulse, 500 Hz, triplet tone with a PW of 200 m sec, aPRI of 310 msec. When the HR alarm is set or
the pacer is on, the lead fault one repeats at a repetition interval of 20 seconds.
Visual: Lead Fault condition causes a ”LEAD FAULT” message to be displayed on the trace along with a dashed
line the width of the trace. The text is 0.18" high and is the color of the display text. The dashed line is 5" long, the
width of the display. The signal is not modulated.
Physiological Alarms (SpO2):
Audible: See Heart Rate Alarm
Visual: Physiological alarms cause the displayed parameter to flash at 2 Hz. Color is amber, white or the same as
the display colored text.
Mute Duration: 90 seconds.