PT-9000C
Features:
Main unit: Portable
Dimensions: L320xW205xH410
Weight: 9.8kg
Specifications:
1. Defibrillator.
● Defibrillator type: Manual, Synchronized, Asynchronized,
● Energy accuracy: ∠+1%
● Energy selection: 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360joules (nominal at a resistance of 50)
● Charging time: Maximum 10 seconds to 360 Joules
● Standard Adult/Pediatric Paddles Reusable external adult paddles (pediatric paddles integrated)
2. Power requirements.
● AC Power supply:100V~240V,50Hz/60 Hz
● Vehicle Voltage (Option) :DC 12V
3. Internal Battery Backup
● Battery type: Rechargeable lead-acid battery (12V 2.0Ah X2)
● Charging time: Time-Minimum of 4 hours for full charging
● Battery charging: During AC Power Supply operation of the device.
● Charging /Low Battery Indication: Red LED
● Battery Capacity: 100% of the battery will provide 120-minmonitoring; and 35 discharges at 360 joules.
4. Display
● LCD Dimensions: 7-inch
● Type: High resolution true-color graphic
● Resolution: 480X234
5. ECG
● ECG lead: Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V1~V6
● S-T segment analysis: -2.0~2.0mv
● Arrhythmia analysis: yes
● Protection: With stand 4000vAc/50Hz voltage in isolation and work against
● Electrosurgical knife and defibrillation
6. Respiration
● Measurement method: Thoracic impedance
7. NIBP
● Working mode: Manual/Automatic/stat (5 minutes)
● Method: Automatic oscillation
● Cuff type: standard Adult; optional Pediatric/Neonatal
8. Temperature
● Measurement range 20~45℃
● Resolution 0.1℃
9. Pulse Oximetry (SPO2)
● Display: SPO2 value, pulse histogram, waveform, Pulse
● Range: 0~99%for adult, pediatric and neonatal patients
● Probe: standard adult finger clip
● Optional pediatric Y-type clip and neonatal wrap
10. Pulse range
● Pulse range: 0-255bpm
11. Standard parameter & configuration
● ECG/RESP/SPO2/TEMP/PR/NIBP/DEFIBRILLATOR
12. Optional parameter
● Recorder, Li-ion battery (11.1V 4Ah X 2)
Features:
Main unit: Portable
Dimensions: L320xW205xH410
Weight: 9.8kg
Specifications:
1. Defibrillator.
● Defibrillator type: Manual, Synchronized, Asynchronized,
● Energy accuracy: ∠+1%
● Energy selection: 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360joules (nominal at a resistance of 50)
● Charging time: Maximum 10 seconds to 360 Joules
● Standard Adult/Pediatric Paddles Reusable external adult paddles (pediatric paddles integrated)
2. Power requirements.
● AC Power supply:100V~240V,50Hz/60 Hz
● Vehicle Voltage (Option) :DC 12V
3. Internal Battery Backup
● Battery type: Rechargeable lead-acid battery (12V 2.0Ah X2)
● Charging time: Time-Minimum of 4 hours for full charging
● Battery charging: During AC Power Supply operation of the device.
● Charging /Low Battery Indication: Red LED
● Battery Capacity: 100% of the battery will provide 120-minmonitoring; and 35 discharges at 360 joules.
4. Display
● LCD Dimensions: 7-inch
● Type: High resolution true-color graphic
● Resolution: 480X234
5. ECG
● ECG lead: Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V1~V6
● S-T segment analysis: -2.0~2.0mv
● Arrhythmia analysis: yes
● Protection: With stand 4000vAc/50Hz voltage in isolation and work against
● Electrosurgical knife and defibrillation
6. Respiration
● Measurement method: Thoracic impedance
7. NIBP
● Working mode: Manual/Automatic/stat (5 minutes)
● Method: Automatic oscillation
● Cuff type: standard Adult; optional Pediatric/Neonatal
8. Temperature
● Measurement range 20~45℃
● Resolution 0.1℃
9. Pulse Oximetry (SPO2)
● Display: SPO2 value, pulse histogram, waveform, Pulse
● Range: 0~99%for adult, pediatric and neonatal patients
● Probe: standard adult finger clip
● Optional pediatric Y-type clip and neonatal wrap
10. Pulse range
● Pulse range: 0-255bpm
11. Standard parameter & configuration
● ECG/RESP/SPO2/TEMP/PR/NIBP/DEFIBRILLATOR
12. Optional parameter
● Recorder, Li-ion battery (11.1V 4Ah X 2)
content is empty!